ASME B16.5 flanged sensors
Sensor variantsSITRANS FCS400 sensors are available in a wide range ofprocess connections. The available combinations of type, sensorsize and connection size are shown in the tables below.
Standard sensors
Sensor | Connection | EN 1092-1 B1, PN 40 | EN 1092-1 B1, PN 63 | EN 1092-1 B1, PN 100 | EN 1092-1 B1, PN 1602) | EN 1092-1 D Nut, PN 40 | EN 1092-1 D Nut, PN 63 | EN 1092-1 D Nut, PN 100 | EN 1092-1 D Nut, PN 1602) | ANSI B16.5-2009, class 150 | ANSI B16.5-2009, class 300 | ANSI B16.5-2009, class 600 | ANSI B16.5-2009, class 9001) | ISO 228-1 G pipe thread | ASME B1.20.1 NPT pipe thread | DIN 11851 hygienic screwed | DIN 32676 hygienic tri-clamp | DIN 11864-1A aseptic screwed | DIN 11864-2A aseptic flanged | DIN 11864-3A aseptic clamp | ISO 2852 hygienic clamped | ISO 2853 hygienic screwed | SMS 1145 hygienic screwed | 12-VCO-4 quick connect | JIS B2220:2004/10K | JIS B2220:2004/20K | JIS B2220:2004/40K | JIS B2220:2004/63K |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Standard:7ME461.-... | ||||||||||||||||||||||||||||
DN 15(½") | DN 6(¼") | ● | ● | |||||||||||||||||||||||||
DN 10(3/8") | ● | |||||||||||||||||||||||||||
DN 15(½") | ● | |||||||||||||||||||||||||||
DN 20(¾") | ● | ● | ||||||||||||||||||||||||||
DN 25(1") | ● | ● | ||||||||||||||||||||||||||
DN 25(1") | DN 15(½") | |||||||||||||||||||||||||||
DN 25(1") | ||||||||||||||||||||||||||||
DN 32(1¼") | ● | |||||||||||||||||||||||||||
DN 40(1½") | ● | |||||||||||||||||||||||||||
DN 50(2") | DN 25(1") | |||||||||||||||||||||||||||
DN 40(1½") | ● | |||||||||||||||||||||||||||
DN 50(2") |
1) Apply class 600 p and t ratings for class 900 and class1500 flanges.
2) P and T rating as PN 100.
Hygienic sensor variants (in preparation)
The hygienic sensors all have polished internal wetted material anda maximum internal surface roughness Ra < 0.8 µm andare EHEDG and 3A approved.
Aseptic flanged process connections
The aseptic flanges offered for FCS400 conform with the standardDIN 11864-2A BF-A. The flange fitted to the sensor istherefore the back flange and the seal is an O-ring.
The flange dimensions in the FCS400 program are as follows:
Size DN | Pipe | Bore d1 | Ring OD d11 | Bolt circle d5 | Bolt holes | Flange diameter d10 |
---|---|---|---|---|---|---|
10 | 13 × 1.5 | 10 | 22.4 | 37 | 4 × ∅9 | 54 |
15 | 19 × 1.5 | 16 | 28.4 | 42 | 59 | |
20 | 23 × 1.5 | 20 | 32.4 | 47 | 64 | |
25 | 29 × 1.5 | 26 | 38.4 | 53 | 70 | |
32 | 35 × 1.5 | 32 | 47.7 | 76 | ||
40 | 41 × 1.5 | 38 | 53.7 | 65 | 82 | |
50 | 53 × 1.5 | 50 | 65.7 | 77 | 94 | |
65 | 70 × 2.0 | 66 | 81.7 | 95 | 8 × ∅9 | 107 |